Received Your Fire Inspection Notice?


Schedule your inspection and we'll take care of the rest…We've been doing just that since 2015.

Request a Quote

Received Your Fire Inspection Notice?


Schedule your inspection and we'll take care of the rest…We've been doing just that since 2015.

Request a Quote

Received Your Fire Inspection Notice?


Schedule your inspection and we'll take care of the rest…We've been doing just that since 2015.

Request a Quote

Received a Renewal Notice?

Due for a Compliance Test?

Insurance provider requesting a Fire System inspection?

Received a Notice of Violation?

Request a quote for any service and we will provide a complete quote for your property.

You will be invited to authorize your inspection thru our 1 2 3 SAFETY Customer Portal.

Our inspectors will schedule, inspect and report on the condition of your fire protection systems.

If repairs are required, the repairs must be performed prior to inspection making it to the compliance step.

Schedule Service

Schedule Any Of The Following

Basic and Complex Fire Alarm Systems


Certified Testing and Repair.

Automatic Sprinkler Systems


Certified Testing and Repair.

Class II Standpipe


Certified Testing and Repair.

Fire Escape Assemblies


Certified Testing and Repair.

+ More

Central Station Testers

Automatic Closing Fire Assemblies Testers

Class I Standpipe Testers

Class III Standpipe Testers

Mechanical Smoke Proof Enclosures Testers

Fire Pumps Testers

Combined Standpipe Testers

Central Station Testers

Automatic Closing Fire Assemblies Testers

Class I Standpipe Testers

Class III Standpipe Testers

Mechanical Smoke Proof Enclosures Testers

Fire Pumps Testers

Combined Standpipe Testers

Combined Standpipe Testers

Your building has successfully passed the inspection.

Our inspectors will submit a report to correct fire department and jurisdiction.

You will be able to pay for your inspection via your 1 2 3 SAFETY Customer Portal.

You will be able to access your report and all other records via the 1 2 3 SAFETY Customer Portal.

Schedule Your Service Today

Schedule Your Service Today

Meet the Team


Castle Todt

Client Services Mgr.


Street Taco? Asada Mushroom

Disneyland Ride? Splash Mountain

Hobby? Sewing

Mike Verdin

Systems Tech


Street Taco? Carne Asada

Disneyland Ride? Cars Ride

Hobby? Photography

Frequently Asked Questions


  • Are the alarms going to ring during an automatic fire sprinkler test?

    It depends on the fire alarm panel and building.


    If I could disable the fire alarm panel then there will be no audible/visuals for the most part.


    We must test the sprinkler bell and waterflow devices to ensure they function properly.

  • Are the testers required to enter every unit?

    Depends if the fire alarm system has devices installed to notify people in each unit.


    For Automatic Sprinkler 5-year tests, inspectors are required to enter every unit in order to keep your property in compliance

  • What is a Manual Pull Station?

    Fire alarm initiating device, that requires a person to activate in the event of a fire. This will activate building alarms and in some cases, dispatch fire department.

  • What is a Mini Horn?

    A device that emits an audible alarm to notify people on an alarm condition in a building.

  • What does the date mean on a fire hose?

    Fire hoses are marked with the date manufacture. 

  • What does the date mean on a fire extinguisher?

    The date on a tagged fire extinguisher is when it was last serviced/inspected. 

  • How do you test the response time in a fire sprinkler?

    There is a waterflow device located on the sprinkler system that simulates a sprinkler head activating.


    As part of your test, we will activate this waterflow device. This initiates a signal to the fire alarm panel, which then activates the alarm.

  • What is a Dorothy Mae system?

    Dorothy May is a requirement for residential buildings dating pre-1943 residential, which have 3 or more stories.


    This properties must meet certain fire safety requirements including: All required stair shafts and area separation doors shall be equipped with self-closing devices to release the door by the activation of smoke detectors.


    Sprinklers required to be installed over the doors leading into the corridors or stairs shall discharge water equivalent to a ½ inch orifice head.

  • What is a Sprinkler Riser?

    Fire sprinkler riser is like a bridge between your water supply and the sprinkler pipes in your building.

  • Why do the testers check the mini-horn, can’t the tenant do that?

    In order to keep your property in compliance, our licensed inspectors are responsible for visually and audibly verifying the mini-horns are operating properly. 

  • How often do fire extinguishers get inspected?

    Your most common fire extinguisher requires an annual inspection.


    In addition, they require to be hydrotested every 5 years.


    Keep in mind that a large variety of fire extinguisher types and inspections requirements exist and may require a completely different inspection interval then mentioned above.